Koolance PC3-736SL Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware Koolance PC3-736SL. Koolance PC3-736SL User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 0
Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954
Other Technology Pending U.S. & World-Wide Patents
Superior Liquid Cooling Systems
®
English v1.01
PC3-700 Series
Users Manual
PC3-700 Series
Users Manual
www.koolance.com
ISO
9001
Printed in Korea
Vedere la pagina 0
1 2 3 4 5 6 ... 28 29

Sommario

Pagina 1 - User’s Manual

Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954Other Technology Pending U.S. & World-Wide PatentsSuperior Liquid Cooling Sys

Pagina 2 - User Manual

5User ManualLED Display PanelTemperature SensorsPC3-700 systems can monitor up to 3 temperature sensors (included). The fi rst LED digit indicates whic

Pagina 3

6Alarm SettingsBy default, the Koolance audio alarm will sound if any sensor reaches 55ºC (131ºF). When the system alarm sounds, the LED temperature w

Pagina 4 - Table of Contents

7User ManualChapter2Connecting PC3-700 Systems

Pagina 5 - Required Tools

8Power ConnectionYou may begin the installation of your Koolance system by mounting a power supply in the chassis. The liquid cooling system requires

Pagina 6 - Chapter1

9User ManualATX Power SwitchThe ATX “pass through” lead is responsible for shutting off your computer if sensor channel #1 reaches 3ºC (5ºF) above th

Pagina 7 - Advantages of Water Cooling

10Depending on the cooling blocks (“coolers”) in your Koolance system and nozzle sizes (1/4”, 3/8”, etc.), they may be connected in series, parallel,

Pagina 8

11User ManualThe maximum number of coolers allowed in a system will depend upon your specifi c thermal requirements and hose confi guration. It is not u

Pagina 9 - PC3-700 System Diagram

12Each tubing connection uses a threaded compression fi tting (“hose screw”) to keep it secure. To connect these components:Connecting HosesThread a ho

Pagina 10 - LED Display Panel

13User ManualDisconnecting HosesNozzles are designed to attach tightly. If you need to remove a hose for any reason, it may not pull off easily, even

Pagina 11

14Hose LengthsRemove the threaded compression fi ttings from both radiator nozzles inside the case and attach the supplied 10mm (3/8”) tubing to each r

Pagina 12 - Chapter2

iUser ManualThis User Manual is updated regularly. Please be sure to check our support page for a newer version of this guide: www.koolance.com/suppor

Pagina 13 - Power Connection

15User ManualContinue connecting all of your coolers in the system until there are no longer any open tube ends.Liquid CoolersYou should now install t

Pagina 14 - ATX Power Switch

16Chapter3Filling & MaintenanceFilling & Maintenance

Pagina 15

17User ManualTesting & FillingOnce all of the coolers have been connected, the system can be fi lled with coolant. The refi ll tap is located on top

Pagina 16

18The liquid coolant should be fi lled up to about 1.5 cm (1/2”) from the reservoir’s top. This small gap will catch air as it circulates through the s

Pagina 17 - Connecting Hoses

19User ManualThe coolant in your system should be emptied for any of the below reasons. Unless replacing the liquid coolant, it can also be reused.1.

Pagina 18 - Disconnecting Hoses

20We hope your Koolance system will provide you with years of reliable cooling performance. To help avoid unnecessary RMA issues, we have prepared thi

Pagina 19 - Hose Lengths

21User Manual4. After the system has been on for awhile, the temperature alarm sounds...Make sure the LED temperature is at or above your preset alarm

Pagina 20 - Liquid Coolers

226. My system appears to be leaking fl uid...Since users are allowed to confi gure their own coolers and clamps, it is possible a connection was not pr

Pagina 21 - Chapter3

23User ManualLimited WarrantyDisclaimerKoolance Incorporated (“Koolance”) warrants each new Koolance liquid-cooled system (“the system”), against defe

Pagina 22 - Testing & Filling

Protected by U.S. Patents 6,664,627; 6,313,990; 6,234,240; 5,731,954Other Technology Pending U.S. & World-Wide PatentsSuperior Liquid Cooling Sys

Pagina 23

iiWARNING: The Koolance liquid & coolant pack contain chemicals which may be harmful or fatal if swallowed. KEEP THIS AND ALL DANGEROUS CHEMICAL

Pagina 24 - Draining & Maintenance

iiiUser ManualTable of ContentsIntroduction 1PC3-700 System Diagram ... 4LE

Pagina 25 - Troubleshooting

iv PC3 Series Systems: - motherboard standoffs & insulating washers - motherboard, slot card, 5.25” drive, and fl oppy screws - hard drive moun

Pagina 26

1User ManualChapter1Introduction

Pagina 27

2 Congratulations on your purchase of a Koolance system!As the most sophisticated product of its kind, Koolance offers many unique features found now

Pagina 28 - Disclaimer

3User ManualThe heart of a liquid cooling system is the pump. This device pushes liquid through each cooler and into the heat exchanger. Koolance syst

Pagina 29

4 IntroductionPC3-700 System DiagramReservoir & Pumps Radiator Cooling FansReservoir Refi ll TapRadiator (Primary Heat Exchanger)Power Circuit B

Commenti su questo manuale

Nessun commento